Fixed Rail Welding Machine

Technical Parameters:

Parameter
Unit
The Fixed Rail Welding Machine
Rated Input Voltage
V
380±10% (power grid power supply)
400±5% (diesel generator power supply)
Power Frequency
Hz
50
AC Welding Power Supply Phase
Phase
2
Auxiliary Power Supply Phase
Phase
3
Welding Circuit DC Resistance
μΩ
Less than 20
Max. Short-circuit Power
KVA
No more than 400
Rated Input Capacity
KVA
200 (duty cycle 50%)
Max. Primary Current
A
More than 1000
Hydraulic System Max. Oil Pressure
MPa
15
Max. Upsetting Force
Ton
60
Max. Clamping Force
Ton
150
Welding Machine Weight
Kg
7000
Size: Width x Height x Length
mm
1350 x 2280 x 3145
60 kg/m Rail Welding Time (Continuous Flash/Pulse Flash)
Sec
180 / 80
Max. Welding Efficiency
Number Per Hour
12-16
Suitable For Rail Type
38,43,50,60,75 and All Series of Rails